Research dossier v0.3 / Appendix

Prototype 1 Protocol

A staged laboratory protocol for controlled red/orange atmospheric emission tests.

PhaseActionsData to save
0 SafetyClosed chamber, earth, interlock, emergency stop, extraction, ozone handling, two operators.Signed checklist, setup photos, sensor state.
1 Optical calibrationRAW camera, manual focus, fixed exposure/gain, spectrum calibrated with known sources.Dark frames, references and red/orange calibration.
2 Dry airSlow voltage/frequency sweep to first visible threshold.Voltage, current, frequency, spectrum, thermal video, ozone and RH.
3 HumidityRepeat at controlled relative humidity levels.Compare H-alpha/OH/N2 and threshold.
4 Water/salt aerosolDistilled and weak saline aerosol without wetting electrodes.Na 589 nm change, orange shift and stability.
5 Visible thresholdRamp power around on/off threshold.Ignition/extinction point, color and spectrum.
6 Pulsed modePulses from just below threshold.Appearance, decay, thermal behavior.
7 Negative controlsRepeat with geometry changes and no aerosol/humidity.Show what is real emission vs artifact.